Do you have a power series DSC security system ?

Trouble light help

  • On the keypad enter [*] [2]
  • Some keypads will describe the Trouble (full-message keypads); others will only identify the Trouble number (fixed-message and LED keypads)
  • DSC Power Series Trouble Codes

    Trouble [1] - Service Required

    Please call Land and Sea security for further assistance

    Trouble [2] - AC Failure

    AC power no longer being supplied to the security system

    Trouble [3] - Telephone Line Trouble

    No dial tone detected at the alarm panel

    Trouble [4] - Failure to Communicate

              System could not reach central station

     

    To clear a fail to communicate condition you must call central station to place your account on test followed by setting off your alarm to generate a signal to central station, Call the central station back when you are complete to see if they recieved the code from your system

    Trouble [5] - Zone Fault

    A zone is in a trouble condition and may not provide an alarm (including fire zones)

    Trouble [6] - Zone Tamper

    Only for zones that are programmed for double end-of-line-resistors

    Trouble [7] - Device Low Battery

    Wireless device exhibits a low battery condition

    Trouble [8] - Loss of System Time

    Changing the Time and Date:

    • On the keypad enter [*] [6]
    • Enter the Master Code
    • Press [1]
    • Enter the Time is Hours and Minutes using 24 Hour format (00:00 to 23:59)
    • Enter the Date in Months, Days and Years (MM DD YY)
    • Example 5:30 pm March 1, 2008 (1 7 3 0 0 3 0 1 0 8)
    • Press [#] to return to the ready state

    You can reach us at 203 877 0150 for tech help